Seismic (1993 BOCA, 1996 BOCA, 1999 BOCA):

(Revised:  04/01/08)

Seismic Hazard Exposure Group 1:  All occupancies except those listed below.

Seismic Hazard Exposure Group 2:  Buildings which have a substantial public hazard due to occupancy or use, including buildings containing any one or more of the indicated occupancies.

1.)     Use Group A in which more than 300 people congregate in one area.

2.)     Use Group E with an occupant load greater than 250.

3.)     Use Group B used for college or adult education with an occupant load greater than 500.

4.)     Use Group I-2 with an occupant load greater than 50, not having surgery or emergency treatment facilities.

5.)     Group I-3.

6.)     Power generating stations and other public utility facilities not included in Seismic Hazard Exposure Group 3.

7.)     Any other occupancy with an occupant load greater than 5000.

Seismic Hazard Exposure Group 3:  Buildings having essential facilities which are required for post-earthquake recovery, including buildings containing any one or more of the indicated occupancies.

1.)     Fire, rescue and police stations.

2.)     Use Group I-2 having surgery or emergency treatment facilities.

3.)     Emergency preparedness centers.

4.)     Post-earthquake recovery vehicle garages.

5.)     Power-generating stations and other utilities required as emergency backup facilities.

6.)     Primary communication facilities.

7.)     Highly toxic materials as defined by 307.0 where the quantity of the material exceeds the exempt amounts of Section 307.8.

 

See also:

§ Building Loading - Seismic