Warehouse - Calculations
Overages not included
(Revised: 09/05/2023)

MR24 Roof Fasteners


Punched Secondary Fastener Options

Structural

Mark

Condition

Sliding Panel Clip

Mark

ScruBolt 1” Hex Head

097196

No T. Block

Short

Short (FM)

0560440

0560743

ScruBolt 1” Hex Head

097196

Thermal Blocks

< 6” Blanket

Tall

Tall (FM)

0560741

0560744

ScruBolt 2” Hex Head

097222

Thermal Blocks

> 6” Blanket

Extra Tall

0560745

ScruBolt 1 ¼” Hex Head

096932

Thermal Blocks

TBS (Bridge)

< 8” UF Blanket

Tall

0560741

ScruBolt 1 ¼” Hex Head

096932

Thermal Blocks

TBS (Bridge)
= 9” UF Blanket

Extra Tall

0560745

MR24 Roof Fasteners – High Uplift


Punched Secondary Fastener Options

High Uplift Options: Seam Clamp, Spacer w/ ScruBolts, Space w/ (2) Structural Fasteners

Structural

Mark

Condition

Sliding Panel Clip

Mark

ScruBolts don’t change

 

 

 

Seam Clamp

0560612

ScruBolt 1” Hex Head

 

097196

No T. Block

Clip Spacer

Short (FM)

0560746

0560743

ScruBolt 1” Hex Head

 

097196

Thermal Blocks

< 6” Blanket

Clip Spacer

Tall (FM)

0560746

0560744

ScruBolt 1” Hex Head

 

097196

Thermal Blocks

> 6” Blanket

Clip Spacer

X-Tall (FM)

0560746

0560745

ScruBolt 1” Hex Head

(T-3) 1 ¼” Hex Head

097196

097460

No T. Block

 

Clip Spacer

Short (FM)

0560746

0560743

ScruBolt 1” Hex Head

(T-3) 1 ¼” Hex Head

097196

097460

Thermal Blocks

< 6” Blanket

Clip Spacer

Tall (FM)

0560746

0560744

ScruBolt 1” Hex Head

(T-3) 1 ¼” Hex Head

097196

097460

Thermal Blocks

> 6” Blanket

Clip Spacer

X-Tall (FM)

0560746

0560745

CMR24 Roof Fasteners


Punched Secondary Fastener Options

Structural

Mark

Condition

Sliding Panel Clip

Mark

ScruBolt 2 ¼” Hex Head

097270

3/4" Thermax

Short

Short (FM)

0560440

0560743

ScruBolt 3 ½” Hex Head

097271

1 3/4" Thermax

Short 

Short (FM)

0560440

0560743

BRII Roof Fasteners

Punched Secondary

Structural Fastener Options

Description

Mark

Insulation

ScruBolt 1” Hex Head

ScruBolt 1 ¼” Hex Head

097196

096932

>0” < 2”

>2” < 4”

ScruBolt 1” Hex Head

ScruBolt 1 ¼” Hex Head

(Match Roof Color)

097196SPR

096932SPR

>0” < 2”

>2” < 4”

ScruBolt 7/8” Hex Hd SS

ScruBolt 1 ¼” Hex Hd SS

095984

097104

>0” < 2”

>2” < 4”

Lock-Rivet 1 3/32” “B” Hd

Lock-Rivet 1 11/32” “B” Hd

096306

096583

>0” < 2”

>2” < 4”

 

Unpunched Secondary

Structural Fastener Options

Description

Mark

Insulation

(T-3) 1 ¼” Hex Head

097230-***

>0” < 3”

(T-3) 1 ¼” Hex Head SS

097373

>0” < 3”

 

Stitch Fastener Options

Description

Mark

(T-1) 7/8” Hex Head

097357-***

(T-1) 7/8” Hex Head SS

0097374

Lock-Rivet 1 3/32” “B” Hd

0096306

VSR Roof Fasteners


Fastener Options

Structural

Mark

Insulation

Thermal Blocks

Sliding Clip

Mark

(T-3) 1 ¼” Hex Head

(T-5) 1 ½” Hex Head

55320 (Purlin)

56104 (Joist)

< 1” Blanket

No

2”

 

80062

(T-3) 1 ¼” Hex Head

(T-5) 1 ½” Hex Head

55320 (Purlin)

56104 (Joist)

> 2” < 6” Blanket

No

2 ½”

 

80060

(T-3) 1 ¼” Hex Head

(T-5) 1 ½” Hex Head

55320 (Purlin)

56104 (Joist)

> 6” Blanket

No

3”

 

80061

(T-3) 1 ¼” Hex Head

(T-5) 1 ½” Hex Head

55320 (Purlin)

56104 (Joist)

< 1” Blanket

560192

3”

 

80061

(T-3) 1 ¼” Hex Head

(T-5) 1 ½” Hex Head

55320 (Purlin)

56104 (Joist)

> 2” < 6” Blanket

560192

3 ½”

560344

(T-3) 1 ¼” Hex Head

(T-5) 1 ½” Hex Head

55320 (Purlin)

56104 (Joist)

> 6” Blanket

560192

4”

560345

BRII Wall Fasteners
BRII Partition Exterior Wall Fasteners

Punched Secondary

Structural Fastener Options

Description

Mark

Insulation

ScruBolt 7/8” Torx Head

ScruBolt 1 1/2” Torx Head

097361-***

097362-***

>0” < 2”

>2” < 4”

ScruBolt 1” Hex Head

ScruBolt 1 1/4” Hex Head

097196

096932

>0” < 2”

>2” < 4”

ScruBolt 1” Hex Head

ScruBolt 1 1/4” Hex Head

(Match Roof Color)

097196SPR

096932SPR

>0” < 2”

>2” < 4”

ScruBolt 7/8” Hex Hd SS

ScruBolt 1 1/4” Hex Hd SS

095984

097104

>0” < 2”

>2” < 4”

Lock-Rivet 1 3/32” “B” Hd

Lock-Rivet 1 11/32” “B” Hd

096306

096583

>0” < 2”

>2” < 4”

Unpunched Secondary

Structural Fastener Options

Description

Mark

Insulation

(T-3) 1 1/4” Torx Head

097365-***

>0” < 3”

(T-3) 1 1/4” Hex Head

097230-***

>0” < 3”

(T-3) 1 1/4” Hex Head SS

097373

>0” < 3”

Stitch Fastener Options

Description

Mark

(T-1) 3/4” Torx Head

097364-***

(T-1) 7/8” Hex Head

097357-***

(T-1) 7/8” Hex Head SS

0097374

Lock-Rivet 1 3/32” “B” Hd

0096306

Shadowall Wall Fasteners


Punched Secondary Fastener Options

Structural

Mark

Insulation

Stitch

Mark

ScruBolt 7/8” Torx Head

ScruBolt 1 ½” Torx Head

097361-***

097362-***

>0” < 4”

>4” < 8”

(T-1) 3/4” Torx Head

 

097364-***


Unpunched Secondary Fastener Options

Structural

Mark

Insulation

Stitch

Mark

(T-3) 1 ¼” Torx Head

097365-***

>0” < 6”

(T-1) 3/4” Torx Head

097364-***


Unpunched Secondary w/ ScruBolts Top and Bottom (Base, Low Eave, High Eave, Gable)

Structural

Mark

Insulation

 

 

ScruBolt 7/8” Torx Head

ScruBolt 1 ½” Torx Head

097361-***

097362-***

>0” < 4”

>4” < 8”

 

 

eShadowall Wall Fasteners


Punched Secondary Fastener Options

Structural

Mark

Insulation

Stitch

Mark

ScruBolt 3 ½” Torx Head

097604-***

>0” < 8”

(T-1) 3/4” Torx Head

097364-***

 


Unpunched Secondary Fastener Options

Structural

Mark

Insulation

Stitch

Mark

(T-3) 3 1/8” Torx Head

097605-***

>0” < 8”

(T-1) 3/4” Torx Head

097364-***

 


Optional Unpunched Secondary w/ ScruBolt Top and Bottom (Base, Low Eave, High Eave, Gable)

Structural

Mark

Insulation

 

 

ScruBolt 3 ½” Torx Head

097604-***

>0” < 8”

 

 

StylWall Wall Fasteners


Fastener Options

Structural

Mark

Insulation

Stitch

Mark

(T-3) ¾” Hex Head

097295

0”

(T-1) 7/8” Hex Head

097357UNPNTD

(T-3) 1 ¼” Hex Head

097296

>0” < 6”

(T-1) 7/8” Hex Head

097357UNPNTD

eStylWall Wall Fasteners


Fastener Options

 

Structural

Mark

Insulation

Stitch

Mark

(T-3) 3” Hex Head

55310

>0” < 8”

(T-1) 7/8” Hex Head

097357UNPNTD

BRII Lite-Panl Fasteners


Punched Secondary Fastener Options

Structural

Mark

Insulation

Stitch

Mark

ScruBolt 7/8” Torx Head

ScruBolt 1 ½” Torx Head

097361-***

097362-***

>0” < 2”

>2” < 4”

Lock-Rivet 1 3/32” “A” Hd Lite-Panl on top

096295

 

ScruBolt 7/8” Torx Head

ScruBolt 1 ½” Torx Head

097361-***

097362-***

>0” < 2”

>2” < 4”

(T-1) 7/8” Hex Head

Lite-Panl behind wall panel

097357-***

 

Lock-Rivet 1 3/32” “A” Hd

Lock-Rivet 1 11/32” “A” Hd

096295

096582

>0” < 2”

>2” < 4”

Lock-Rivet 1 3/32” “A” Hd Lite-Panl on top

096295

Lock-Rivet 1 3/32” “A” Hd

Lock-Rivet 1 11/32” “A” Hd

096295

096582

>0” < 2”

>2” < 4”

(T-1) 7/8” Hex Head

Lite-Panl behind wall panel

097357-***

 


Unpunched Secondary Fastener Options

Structural

Mark

Insulation

Stitch

Mark

(T-3) 1 ¼” Torx Head

097365-***

>0” < 3”

Lock-Rivet 1 3/32” “A” Hd Lite-Panl on top

096295

(T-3) 1 ¼” Torx Head

097365-***

>0” < 3”

(T-1) 7/8” Hex Head

Lite-Panl behind wall panel

097357-***

 

Shadowall Lite-Panl Fasteners


Punched Secondary Fastener Options

Structural

Mark

Insulation

Stitch

Mark

ScruBolt 7/8” Torx Head

ScruBolt 1 ½” Torx Head

097361-***

097362-***

>0” < 4”

>4” < 8”

Lock-Rivet 1 3/32” “A” Hd Lite-Panl on top

096295

ScruBolt 7/8” Torx Head

ScruBolt 1 ½” Torx Head

097361-***

097362-***

>0” < 4”

>4” < 8”

(T-1) 3/4” Hex Head

Lite-Panl behind wall panel

097364-***

 


Unpunched Secondary Fastener Options

Structural

Mark

Insulation

Stitch

Mark

(T-3) 1 ¼” Torx Head

097365-***

>0” < 6”

Lock-Rivet 1 3/32” “A” Hd Lite-Panl on top

096295

(T-3) 1 ¼” Torx Head

097365-***

>0” < 6”

(T-1) 3/4” Hex Head

Lite-Panl behind wall panel

097364-***

 


Optional Unpunched Secondary w/ ScruBolt Top and Bottom (Base, Low Eave, High Eave, Gable)

Structural

Mark

Insulation

 

 

ScruBolt 7/8” Torx Head

ScruBolt 1 ½” Torx Head

097361-***

097362-***

>0” < 4”

>4” < 8”

 

 

BRII Liner / Partition Liner
BRII Facade / Parapet Back Sheet Fasteners

Structural Fastener Options

Description

Mark

Insulation

(T-3) 1 1/4” Torx Head

097365-***

>0” < 3”

(T-3) 1 1/4” Hex Head

097230-***

>0” < 3”

(T-3) 1 1/4” Hex Head SS

097373

>0” < 3”

Stitch Fastener Options

Description

Mark

(T-1) 3/4” Torx Head

097364-***

(T-1) 7/8” Hex Head

097357-***

(T-1) 7/8” Hex Head SS

0097374

Lock-Rivet 1 3/32” “B” Hd

0096306

BRII, VCI, MOD36 Wall Liner Fasteners
VCI, MOD36 Liner / Partition Liner Fasteners
Shadowall Facade / Parapet Back Sheet Fasteners


Fastener Options

(Torx Head Fasteners are not available with any other fastener types)

Structural

Mark

Insulation

Stitch

Mark

(T-3) 1 ¼” Torx Head

097365-***

n/a

(T-1) 3/4” Torx Head

097364-***

Optional BMC II
w/ ScruBolt Bottom (Base)

Structural

Mark

Insulation

 

 

ScruBolt 7/8” Torx Head

097361-***

n/a

 

 

BRII Canopy / Roof Extension Soffit Fasteners
BRII, VCI Roof Liner Fasteners


Fastener Options

Structural

Mark

Insulation

Stitch

Mark

(T-3) 1 ¼” Hex Head

097230-***

n/a

(T-1) 7/8” Hex Head

097357-***

MOD36 Canopy / Roof Extension Soffit Fasteners
MOD36 (CMR) Roof Liner Fasteners


Fastener Options

Structural

Mark

Insulation

Stitch

Mark

(T-3) 1 ¼” Hex Head

55307

n/a

(T-3) 1 ¼” Hex Head

55307

FP12 Canopy / Roof Extension Soffit Fasteners


Fastener Options

Structural

Mark

Insulation

Stitch

Mark

1” (T-3) Pancake

55312

n/a

n/a

n/a

BRII Roof Covering Warehouse

Warehouse Fastener Options

Standard

Dade County - Only available with Punched Secondary

Fastener Spacing

Structural Fasteners (Round up each Secondary Length to the nearest 1'-0" increment)

Each Lap Purlin = 1 per foot + 1
Each Ridge Purlin =
1 per foot + 1

Each Low Eave Strut = 2 per foot

Each High Eave Strut = 2 per foot

Remaining Purlins = 1 per foot + 1

Stitch Fasteners (Round up each Secondary Length to the nearest 3'-0" increment - 1)

Each Lap Purlin = 3 per Secondary
Each Ridge Purlin = 3
per Secondary

Each Low Eave Strut = 1 per Secondary

Each High Eave Strut = 1 per Secondary

Remaining Purlins = 1 per Secondary
Purlin Spaces > 2'-5 15/16" =
1 per Secondary Space

Dade County Stitch Fastener Spacing

Stitch Fasteners (Round up each Secondary Length to the nearest 3'-0" increment - 1)

Each Side Lap = 1'-0" o.c. Side Lap Length + 1

Mastic Calculation

025390 - Mastic w/ Cubes 3/16" x 1/4" x 40'-0" Roll (Round up to a full Roll per building)

Endlap (Round up Endlap Secondary Length to the nearest 1'-0" increment x 1.296 / 40)

Ridge Lap (Round up Ridge Lap Secondary Length to the nearest 1'-0" increment x 3.356 / 40)

Sidelap (Round up Panel Set Length to the nearest 3'-0" increment - 1 x Sidelap Length / 40)

025392 - Panlastic Tube Sealant - Gray (Round up to a full Tube per building)

Endlap (Round up Endlap Secondary Length to the nearest 1'-0" increment x 0.112 / 20)

Ridge Lap (Round up Ridge Lap Secondary Length to the nearest 1'-0" increment x 0.555 / 20)

MR24, CMR Covering Warehouse

MR24 Clips (Round up each Secondary Length to the nearest 1'-0" increment)

Standard Uplift

Sliding Clip - See chart = 0.5 per linear foot - 1

Fastener - See chart = 0.5 per linear foot - 1

630026 - Trim Clip = 2 per run

096636 - A307 Thin Head Bolt 1/2” x 1 1/4” w/ Nut = 2 per run

LST - Lock Seam Tab = 4 per run

650408 - Spacer Block = 0.5 per linear foot w/ Thermal Blocks, 0 w/o Thermal Blocks

 

Uplift Option 1

Seam Clamps - See chart

 Clamps = 0.5 per linear foot - 1 (except at eave struts)

 

Uplift Option 2

Spacer w/ ScruBolts - See chart

560746 - Clip Spacer = 0.5 per linear foot - 1 (except at eave struts)

Sliding Clip = 2 per Clip Spacer

097196 = 3 per Clip Spacer at Purlins and Bar Joists, 4 per Clip Spacer at Truss Purlins XT

630026 - Trim Clip = 2 per run

096636 - A307 Thin Head Bolt 1/2” x 1 1/4” w/ Nut = 2 per run

LST - Lock Seam Tab = 4 per run

650408 - Spacer Block = 0.5 per linear foot w/ Thermal Blocks, 0 w/o Thermal Blocks

 

Uplift Option 3

Space w/ (2) Structural Fasteners - See chart

560746 - Clip Spacer = 0.5 per linear foot - 1 (except at eave struts)

Sliding Clip = 2 per Clip Spacer

097196 = 2 per Clip Spacer

097460 = 2 per Clip Spacer

630026 - Trim Clip = 2 per run

096636 - A307 Thin Head Bolt 1/2” x 1 1/4” w/ Nut = 2 per run

LST - Lock Seam Tab = 4 per run

650408 - Spacer Block = 0.5 per linear foot w/ Thermal Blocks, 0 w/o Thermal Blocks

 

Panel Laps (Round up each Secondary Length / Staggered Endlap to the nearest 1'-0" increment)

560100 - MR-24 Panel Splice Plate = 0.25 per linear foot

560101 - MR-24 Panel Strap = 0.25 per linear foot

097190UNPNTD - 1/4-20 SS Flange Nut = 1.00 per linear foot

042717 - Mastic- Panlastic Sealant w/ cubes - 1/8" x 1" x 24.25" Strip = 0.25 per linear foot

025392 - Panlastic Tube Sealant = 0. 0318 per linear foot (Round up to a full Tube per building)

 

Ridge (Refer to Vision Trim Kits for Parts and Quantities)

Standard Ridge >¼:12 < 4:12

Seamed Ridge >¼:12 < ½:12

Optional: Interior Ridge Trim

VSR Covering Warehouse

VSR Clips

560344 - VSR 3 1/2" G90 Clip with Blanket Insulation

80061 - VSR 3" G90 Clip without Insulation

80062 - VSR 2" 3 Hole Low Profile Clip with Rigid Board Insulation

1 VSR Clip is required at every intersection of the VSR Sidelap and a secondary member (Excluding the Low Eave Strut).

 

VSR Clip Fasteners

55320 - (T-3) 1/4-14 x 1 1/2", 5/16" Hex Hd (Purlins)

56104 - (T-5) 12-24 x 1 1/2" 5/16" Hex Head (Bar Joist)

Special Purchase - Fastener with Rigid Board Insulation

2 per VSR Clip

 

Thermal Blocks

560192 - VSR 1" x 14.25" Thermal Block

1 per Panel +1 at all VSR Clip Locations (runs).

 

Low Eave

VEA10*** – 10’-0” Eave Angle Support with Blanket Insulation.

Clip Height

Mark

 

Roof Slope

Mark

 2 1/2"

1

1/4 - < 1 1/2

21

3"

2

> 1 1/2 - < 2 1/2

22

3 1/2"

3

> 2 1/2 - < 3 1/2

23

4"

4

> 3 1/2 - < 4 1/2

24

097196 – 3/8” x 1” ScruBolt building length x 2

097230-*** - (T-2) 12-14 x 1 1/4" 5/16" Hex Head SS Cap w/Washer = 3 per linear foot

Low Eave with Rigid Board

 

Mastics and Fasteners at Staggered Laps

Note: Quantities are per lap run (2 required per stager)

0097190UNPNTD - Nut, 1/4-20 SS Flange Nut = 1.5 per linear foot

0560547 - VSR Panel Splice Plate (1'-4") = 0.375 per linear foot

0560562 - Mastic 1/16" x 1" x 40' Roll = 0.0159 per linear foot

0560564 - Mastic 3/16" Dia. x 40' Roll = 0.0047 per linear foot

 

Mastics and Fasteners at Staggered Laps (West Coast Laps)

Note: Quantities are per lap run (2 required per stager)

0097584UNPNTD - T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer = 3 per linear foot

80064- VSR Panel Stiffener (1'-4") = 0.375 per linear foot

0025392- Tube Sealant (Gray) = 0.225 per linear foot

BRII, VSI Wall Covering Warehouse

Fastener Spacing

Structural Fasteners (Round up each Secondary Length to the nearest 1'-0" increment)

Each Lap Girt = 1 per foot + 1
Each Base Member =
2 per foot

Each Low Eave Strut = 2 per foot

Each High Eave Strut = 2 per foot

Each Rake = 2 per foot

Remaining Girts = 1 per foot + 1

Stitch Fasteners (Round up each Secondary Length to the nearest 3'-0" increment - 1)

Each Side Lap = 2'-6" o.c. Side Lap Length + 1

Dade County Stitch Fastener Spacing

Stitch Fasteners (Round up each Secondary Length to the nearest 3'-0" increment - 1)

Each Side Lap = 1'-0" o.c. Side Lap Length + 1

Shadowall, eShadowall Covering Warehouse

Fastener Spacing

Structural Fasteners (Round up each Secondary Length to the nearest 1'-0" increment)

Each Lap Girt = 1 per foot + 1
Each Base Member =
1 per foot + 1

Each Low Eave Strut = 1 per foot + 1

Each High Eave Strut = 1 per foot + 1

Each Rake = 1 per foot + 1

Remaining Girts = 1 per foot + 1

Stitch Fasteners (Round up each Secondary Length to the nearest 3'-0" increment - 1)

Each Side Lap = 3'-0" o.c. Side Lap Length + 1

0650173 - 2" eShadowall Spacer (Not at the Base)

StylWall, eStylWall (Flat / Fluted) Covering Warehouse

Panel Attachments

0570675 - StylWall Reinforcement Clip

Round up each Secondary Length to the nearest 1'-4" increment

Each Girt, Base Member, Low Eave Strut, High Eave Strut, Header, Sill

Structural Fastener - 1 per Reinforcement Clip

0097357UNPNTD - (T-1) 1/4-14 x 7/8", 3/8" Hex Hd w/Washer

>7’-6” Girt Space = 1 per Reinforcement Clip

Panel Design Load > 23 psf = 1 per Reinforcement Clip

Panel Design Load > 41 psf = 1 per Reinforcement Clip and 2’-6” o.c.

0650174 - 1 1/2" eStylWall Spacer

Moduleze Soffit Warehouse

Panel Attachment

Structural Fastener - Each Secondary Member = 1.0 per linear foot + 1

MOD36 Liner / Soffit Warehouse

Panel Attachment

Structural Fastener (Round up each Secondary Length to the nearest 1'-0" increment)

Each Secondary Member = 1.0 per linear foot + 1

Stitch Fasteners (Round up each Secondary Length to the nearest 3'-0" increment - 1)

Each Side Lap = 3'-0" o.c. Side Lap Length + 1

Optional Mastic

025390 - Panlastic w/ Cubes 3/16" x 1/4" x 40' Roll

Sidelap (Round up Sidelap Secondary Lengths to the nearest 1'-0" increment / 40)

Secondary (Round up Secondary Lengths to the nearest 1'-0" increment / 40)

MOD36 at CMR Composite Liner Warehouse

Panel Attachment

Structural Fastener (Round up each Secondary Length to the nearest 1'-0" increment)

Each Secondary Member = 1.0 per linear foot + 1 + 2 fasteners per panel

MOD36 at TLS Liner Warehouse

Panel Attachment

Structural Fastener - Each Secondary Member = 1.0 per linear foot + 1

       Eave Building length x 2

       Gable length + 1

Stitch Fasteners (Round up each Secondary Length to the nearest 3'-0" increment - 1)

Each Side Lap = 3'-0" o.c. Side Lap Length / 2’-6” + 1

Mastic

560562 - Mastic 1/16" x 1" x 40' Roll

Endlap (Round up Endlap Secondary Lengths to the nearest 1'-0" increment x 1.2 / 40)

Sidelap (Round up Sidelap Secondary Lengths to the nearest 1'-0" increment / 40)

025392 - Panlastic Tube Sealant - Gray (Round up to a full Tube per building)

Endlap (Round up Endlap Secondary Lengths to the nearest 1'-0" increment x 0.112 / 20)

Ridge Lap (Round up Ridge Lap Secondary Length to the nearest 1'-0" increment x 0.555 / 20)

Optional CMR Vapor Retarder

560410 - WMPVR (PSKLD) Vapor Retarder = 600'-0" Long Roll x 6’-6” Wide (6’-0” Coverage)

560532 - WMP-50 Vapor Retarder = 600'-0" Long Roll x 6’-6” Wide (6’-0” Coverage)