Punched Secondary Fastener Options |
||||
Structural |
Mark |
Condition |
Sliding
Panel Clip |
Mark |
ScruBolt 1” Hex Head |
097196 |
No T. Block |
Short Short (FM) |
0560440 0560743 |
ScruBolt 1” Hex Head |
097196 |
Thermal Blocks < 6” Blanket |
Tall Tall (FM) |
0560741 0560744 |
ScruBolt 2” Hex Head |
097222 |
Thermal Blocks > 6” Blanket |
Extra Tall |
0560745 |
ScruBolt 1 ¼” Hex Head |
096932 |
Thermal Blocks TBS (Bridge) < 8” UF Blanket |
Tall |
0560741 |
ScruBolt 1 ¼” Hex Head |
096932 |
Thermal Blocks TBS (Bridge) |
Extra Tall |
0560745 |
Punched Secondary Fastener Options High Uplift Options: Seam Clamp,
Spacer w/ ScruBolts, Space w/ (2) Structural
Fasteners |
||||
Structural |
Mark |
Condition |
Sliding
Panel Clip |
Mark |
ScruBolts
don’t change |
|
|
Seam Clamp |
0560612 |
ScruBolt 1” Hex Head |
097196 |
No T. Block |
Clip Spacer Short (FM) |
0560746 0560743 |
ScruBolt 1” Hex Head |
097196 |
Thermal Blocks < 6” Blanket |
Clip Spacer Tall (FM) |
0560746 0560744 |
ScruBolt 1” Hex Head |
097196 |
Thermal Blocks > 6” Blanket |
Clip Spacer X-Tall (FM) |
0560746 0560745 |
ScruBolt 1” Hex Head (T-3) 1 ¼” Hex Head |
097196 097460 |
No T. Block |
Clip Spacer Short (FM) |
0560746 0560743 |
ScruBolt 1” Hex Head (T-3) 1 ¼” Hex Head |
097196 097460 |
Thermal Blocks < 6” Blanket |
Clip Spacer Tall (FM) |
0560746 0560744 |
ScruBolt 1” Hex Head (T-3) 1 ¼” Hex Head |
097196 097460 |
Thermal Blocks > 6” Blanket |
Clip Spacer X-Tall (FM) |
0560746 0560745 |
Punched Secondary Fastener Options |
||||
Structural |
Mark |
Condition |
Sliding
Panel Clip |
Mark |
ScruBolt 2 ¼” Hex Head |
097270 |
3/4" Thermax |
Short Short (FM) |
0560440 0560743 |
ScruBolt 3 ½” Hex Head |
097271 |
1 3/4" Thermax |
Short Short (FM) |
0560440 0560743 |
Punched
Secondary Structural
Fastener Options |
||
Description |
Mark |
Insulation |
ScruBolt
1” Hex Head ScruBolt
1 ¼” Hex Head |
097196 096932 |
>0” < 2” >2”
< 4” |
ScruBolt
1” Hex Head ScruBolt
1 ¼” Hex Head (Match
Roof Color) |
097196SPR 096932SPR |
>0” < 2” >2”
< 4” |
ScruBolt
7/8” Hex Hd SS ScruBolt
1 ¼” Hex Hd SS |
095984 097104 |
>0” < 2” >2”
< 4” |
Lock-Rivet
1 3/32” “B” Hd Lock-Rivet
1 11/32” “B” Hd |
096306
096583 |
>0” < 2” >2”
< 4” |
Unpunched Secondary Structural Fastener Options |
||
Description |
Mark |
Insulation |
(T-3) 1 ¼” Hex Head |
097230-*** |
>0” < 3” |
(T-3) 1 ¼” Hex Head SS |
097373 |
>0” < 3” |
Stitch Fastener Options |
|
Description |
Mark |
(T-1) 7/8” Hex Head |
097357-*** |
(T-1) 7/8” Hex Head
SS |
0097374 |
Lock-Rivet 1 3/32”
“B” Hd |
0096306 |
Fastener Options |
|||||
Structural |
Mark |
Insulation |
Thermal
Blocks |
Sliding
Clip |
Mark |
(T-3) 1 ¼” Hex Head (T-5) 1 ½” Hex Head |
55320 (Purlin) 56104 (Joist) |
< 1” Blanket |
No |
2” |
80062 |
(T-3) 1 ¼” Hex Head (T-5) 1 ½” Hex Head |
55320 (Purlin) 56104 (Joist) |
> 2” < 6”
Blanket |
No |
2 ½” |
80060 |
(T-3) 1 ¼” Hex Head (T-5) 1 ½” Hex Head |
55320 (Purlin) 56104 (Joist) |
> 6” Blanket |
No |
3” |
80061 |
(T-3) 1 ¼” Hex Head (T-5) 1 ½” Hex Head |
55320 (Purlin) 56104 (Joist) |
< 1” Blanket |
560192 |
3” |
80061 |
(T-3) 1 ¼” Hex Head (T-5) 1 ½” Hex Head |
55320 (Purlin) 56104 (Joist) |
> 2” < 6”
Blanket |
560192 |
3 ½” |
560344 |
(T-3) 1 ¼” Hex Head (T-5) 1 ½” Hex Head |
55320 (Purlin) 56104 (Joist) |
> 6” Blanket |
560192 |
4” |
560345 |
Punched
Secondary Structural
Fastener Options |
|||
Description |
Mark |
Insulation |
|
ScruBolt
7/8” Torx Head ScruBolt
1 1/2” Torx Head |
097361-*** 097362-*** |
>0” < 2” >2”
< 4” |
|
ScruBolt
1” Hex Head ScruBolt
1 1/4” Hex Head |
097196 096932 |
>0” < 2” >2”
< 4” |
|
ScruBolt
1” Hex Head ScruBolt
1 1/4” Hex Head (Match
Roof Color) |
097196SPR 096932SPR |
>0” < 2” >2”
< 4” |
|
ScruBolt
7/8” Hex Hd SS ScruBolt
1 1/4” Hex Hd SS |
095984 097104 |
>0” < 2” >2”
< 4” |
|
Lock-Rivet
1 3/32” “B” Hd Lock-Rivet
1 11/32” “B” Hd |
096306
096583 |
>0” < 2” >2”
< 4” |
|
Unpunched
Secondary Structural
Fastener Options |
|||
Description |
Mark |
Insulation |
|
(T-3)
1 1/4” Torx Head |
097365-*** |
>0” < 3” |
|
(T-3)
1 1/4” Hex Head |
097230-*** |
>0” < 3” |
|
(T-3)
1 1/4” Hex Head SS |
097373 |
>0” < 3” |
|
Stitch Fastener Options |
|||
Description |
Mark |
||
(T-1)
3/4” Torx Head |
097364-*** |
||
(T-1) 7/8” Hex Head |
097357-*** |
||
(T-1) 7/8” Hex Head SS |
0097374 |
||
Lock-Rivet 1 3/32”
“B” Hd |
0096306 |
||
Punched Secondary Fastener Options |
||||
Structural |
Mark |
Insulation |
Stitch |
Mark |
ScruBolt 7/8” Torx Head ScruBolt 1 ½” Torx Head |
097361-*** 097362-*** |
>0” < 4” >4” < 8” |
(T-1) 3/4” Torx Head |
097364-*** |
Unpunched Secondary Fastener Options |
||||
Structural |
Mark |
Insulation |
Stitch |
Mark |
(T-3) 1 ¼” Torx Head |
097365-*** |
>0” < 6” |
(T-1) 3/4” Torx Head |
097364-*** |
Unpunched Secondary w/ ScruBolts
Top and Bottom (Base, Low
Eave, High Eave, Gable) |
||||
Structural |
Mark |
Insulation |
|
|
ScruBolt 7/8” Torx Head ScruBolt 1 ½” Torx Head |
097361-*** 097362-*** |
>0” < 4” >4” < 8” |
|
|
Punched Secondary Fastener Options |
||||
Structural |
Mark |
Insulation |
Stitch |
Mark |
ScruBolt 3 ½” Torx Head |
097604-*** |
>0” < 8” |
(T-1) 3/4” Torx Head |
097364-*** |
Unpunched Secondary Fastener Options |
||||
Structural |
Mark |
Insulation |
Stitch |
Mark |
(T-3) 3 1/8” Torx Head |
097605-*** |
>0” < 8” |
(T-1) 3/4” Torx Head |
097364-*** |
Optional Unpunched
Secondary w/ ScruBolt Top and Bottom (Base, Low Eave, High Eave, Gable) |
||||
Structural |
Mark |
Insulation |
|
|
ScruBolt 3 ½” Torx Head |
097604-*** |
>0” < 8” |
|
|
Fastener Options |
||||
Structural |
Mark |
Insulation |
Stitch |
Mark |
(T-3) ¾” Hex Head |
097295 |
0” |
(T-1) 7/8” Hex Head |
097357UNPNTD |
(T-3) 1 ¼” Hex Head |
097296 |
>0” < 6” |
(T-1) 7/8” Hex Head |
097357UNPNTD |
Fastener Options |
||||
Structural |
Mark |
Insulation |
Stitch |
Mark |
(T-3) 3” Hex Head |
55310 |
>0” < 8” |
(T-1) 7/8” Hex Head |
097357UNPNTD |
Punched Secondary Fastener Options |
||||
Structural |
Mark |
Insulation |
Stitch |
Mark |
ScruBolt 7/8” Torx Head ScruBolt 1 ½” Torx Head |
097361-*** 097362-*** |
>0” < 2” >2” < 4” |
Lock-Rivet 1 3/32” “A” Hd
Lite-Panl on top |
096295 |
ScruBolt 7/8” Torx Head ScruBolt 1 ½” Torx Head |
097361-*** 097362-*** |
>0” < 2” >2” < 4” |
(T-1) 7/8” Hex Head Lite-Panl behind wall panel |
097357-*** |
Lock-Rivet 1 3/32” “A” Hd Lock-Rivet 1 11/32” “A” Hd |
096295 096582 |
>0” < 2” >2” < 4” |
Lock-Rivet 1 3/32” “A” Hd
Lite-Panl on top |
096295 |
Lock-Rivet 1 3/32” “A” Hd Lock-Rivet 1 11/32” “A” Hd |
096295 096582 |
>0” < 2” >2” < 4” |
(T-1) 7/8” Hex Head Lite-Panl behind wall panel |
097357-*** |
Unpunched Secondary Fastener Options |
||||
Structural |
Mark |
Insulation |
Stitch |
Mark |
(T-3) 1 ¼” Torx Head |
097365-*** |
>0” < 3” |
Lock-Rivet 1 3/32” “A” Hd
Lite-Panl on top |
096295 |
(T-3) 1 ¼” Torx Head |
097365-*** |
>0” < 3” |
(T-1) 7/8” Hex Head Lite-Panl behind wall panel |
097357-*** |
Punched Secondary Fastener Options |
||||
Structural |
Mark |
Insulation |
Stitch |
Mark |
ScruBolt 7/8” Torx Head ScruBolt 1 ½” Torx Head |
097361-*** 097362-*** |
>0” < 4” >4” < 8” |
Lock-Rivet 1 3/32” “A” Hd
Lite-Panl on top |
096295 |
ScruBolt 7/8” Torx Head ScruBolt 1 ½” Torx Head |
097361-*** 097362-*** |
>0” < 4” >4” < 8” |
(T-1) 3/4” Hex Head Lite-Panl behind wall panel |
097364-*** |
Unpunched Secondary Fastener Options |
||||
Structural |
Mark |
Insulation |
Stitch |
Mark |
(T-3) 1 ¼” Torx Head |
097365-*** |
>0” < 6” |
Lock-Rivet 1 3/32” “A” Hd
Lite-Panl on top |
096295 |
(T-3) 1 ¼” Torx Head |
097365-*** |
>0” < 6” |
(T-1) 3/4” Hex Head Lite-Panl behind wall panel |
097364-*** |
Optional
Unpunched Secondary w/ ScruBolt Top and Bottom (Base, Low Eave, High Eave, Gable) |
||||
Structural |
Mark |
Insulation |
|
|
ScruBolt 7/8” Torx Head ScruBolt 1 ½” Torx Head |
097361-*** 097362-*** |
>0” < 4” >4” < 8” |
|
|
BRII Liner / Partition Liner
BRII Facade / Parapet Back Sheet Fasteners
Structural Fastener Options |
|||
Description |
Mark |
Insulation |
|
(T-3) 1 1/4” Torx Head |
097365-*** |
>0” < 3” |
|
(T-3) 1 1/4” Hex Head |
097230-*** |
>0” < 3” |
|
(T-3) 1 1/4” Hex Head SS |
097373 |
>0” < 3” |
|
Stitch Fastener Options |
|||
Description |
Mark |
||
(T-1) 3/4” Torx Head |
097364-*** |
||
(T-1) 7/8” Hex Head |
097357-*** |
||
(T-1) 7/8” Hex Head
SS |
0097374 |
||
Lock-Rivet 1 3/32”
“B” Hd |
0096306 |
||
BRII, VCI, MOD36 Wall Liner
Fasteners
VCI, MOD36 Liner / Partition Liner Fasteners
Shadowall Facade / Parapet Back Sheet Fasteners
Fastener Options (Torx Head
Fasteners are not available with any other fastener types) |
||||
Structural |
Mark |
Insulation |
Stitch |
Mark |
(T-3) 1 ¼” Torx Head |
097365-*** |
n/a |
(T-1) 3/4” Torx Head |
097364-*** |
Optional
BMC II |
||||
Structural |
Mark |
Insulation |
|
|
ScruBolt 7/8” Torx Head |
097361-*** |
n/a |
|
|
BRII Canopy / Roof Extension
Soffit Fasteners
BRII, VCI Roof Liner Fasteners
Fastener Options |
||||
Structural |
Mark |
Insulation |
Stitch |
Mark |
(T-3) 1 ¼” Hex Head |
097230-*** |
n/a |
(T-1) 7/8” Hex Head |
097357-*** |
MOD36 Canopy / Roof Extension
Soffit Fasteners
MOD36 (CMR) Roof Liner Fasteners
Fastener Options |
||||
Structural |
Mark |
Insulation |
Stitch |
Mark |
(T-3) 1 ¼” Hex Head |
55307 |
n/a |
(T-3) 1 ¼” Hex Head |
55307 |
FP12 Canopy / Roof Extension
Soffit Fasteners
Fastener Options |
||||
Structural |
Mark |
Insulation |
Stitch |
Mark |
1” (T-3) Pancake |
55312 |
n/a |
n/a |
n/a |
BRII Roof Covering Warehouse
Warehouse
Fastener Options Standard Dade County - Only available with Punched Secondary |
Fastener
Spacing Structural
Fasteners (Round
up each Secondary Length to the nearest 1'-0" increment) Each Lap Purlin = 1 per foot + 1 Each Low Eave Strut = 2 per foot Each High Eave Strut = 2 per foot Remaining Purlins = 1 per foot + 1 Stitch
Fasteners (Round
up each Secondary Length to the nearest 3'-0" increment - 1) Each Lap Purlin = 3 per Secondary Each Low Eave Strut = 1 per Secondary Each High Eave Strut = 1 per Secondary Remaining Purlins = 1 per Secondary Dade
County Stitch Fastener Spacing Stitch
Fasteners (Round
up each Secondary Length to the nearest 3'-0" increment - 1) Each Side Lap = 1'-0" o.c. Side
Lap Length + 1 |
Mastic
Calculation 025390
- Mastic
w/ Cubes 3/16" x 1/4" x 40'-0" Roll (Round up to a full Roll
per building) Endlap
(Round
up Endlap Secondary Length to the nearest 1'-0" increment x 1.296 / 40) Ridge
Lap (Round
up Ridge Lap Secondary Length to
the nearest 1'-0" increment x 3.356 / 40) Sidelap
(Round
up Panel Set Length to the nearest 3'-0" increment - 1 x Sidelap Length / 40) 025392
- Panlastic Tube
Sealant - Gray (Round up to a full Tube per building) Endlap
(Round
up Endlap Secondary Length to the nearest 1'-0" increment x 0.112 / 20) Ridge
Lap (Round
up Ridge Lap Secondary Length to the nearest 1'-0" increment x 0.555 /
20) |
MR24, CMR Covering Warehouse
MR24
Clips (Round
up each Secondary Length to the nearest 1'-0" increment) Standard
Uplift Sliding
Clip -
See chart = 0.5 per linear foot -
1 Fastener
-
See chart = 0.5 per linear foot -
1 630026 -
Trim Clip = 2 per run 096636
- A307
Thin Head Bolt 1/2” x 1 1/4” w/ Nut = 2 per run LST
- Lock
Seam Tab = 4 per run 650408
-
Spacer Block = 0.5 per linear foot w/ Thermal
Blocks, 0 w/o Thermal Blocks Uplift
Option 1 Seam
Clamps -
See chart Clamps = 0.5 per
linear foot - 1 (except at eave struts) Uplift
Option 2 Spacer w/ ScruBolts
-
See chart 560746
-
Clip Spacer = 0.5 per linear foot
- 1 (except at eave struts) Sliding
Clip
= 2 per Clip Spacer 097196 = 3 per Clip Spacer at Purlins and Bar
Joists, 4 per Clip Spacer at Truss Purlins XT 630026 -
Trim Clip = 2 per run 096636
- A307
Thin Head Bolt 1/2” x 1 1/4” w/ Nut = 2 per run LST
- Lock
Seam Tab = 4 per run 650408
-
Spacer Block = 0.5 per linear foot w/ Thermal
Blocks, 0 w/o Thermal Blocks Uplift
Option 3 Space w/ (2) Structural Fasteners
-
See chart 560746
-
Clip Spacer = 0.5 per linear foot
- 1 (except at eave struts) Sliding
Clip
= 2 per Clip Spacer 097196 = 2 per Clip Spacer 097460 = 2 per Clip Spacer 630026 -
Trim Clip = 2 per run 096636
- A307
Thin Head Bolt 1/2” x 1 1/4” w/ Nut = 2 per run LST
- Lock
Seam Tab = 4 per run 650408
-
Spacer Block = 0.5 per linear foot w/ Thermal
Blocks, 0 w/o Thermal Blocks |
Panel
Laps
(Round up each Secondary Length / Staggered Endlap to the nearest 1'-0"
increment) 560100
- MR-24
Panel Splice Plate = 0.25 per linear foot 560101
- MR-24
Panel Strap = 0.25 per linear foot 097190UNPNTD -
1/4-20 SS Flange Nut = 1.00 per linear foot 042717 -
Mastic- Panlastic Sealant w/ cubes - 1/8" x
1" x 24.25" Strip = 0.25 per linear foot 025392
- Panlastic Tube
Sealant = 0. 0318 per linear foot (Round up to a full Tube per building) |
Ridge (Refer
to Vision Trim Kits for Parts and Quantities) Standard Ridge >¼:12 <
4:12 Seamed Ridge >¼:12 <
½:12 Optional: Interior
Ridge Trim |
VSR Covering Warehouse
VSR
Clips 560344 - VSR
3 1/2" G90 Clip with Blanket Insulation 80061 - VSR
3" G90 Clip without Insulation 80062 - VSR
2" 3 Hole Low Profile Clip with Rigid Board Insulation 1
VSR Clip is required at every intersection of the VSR Sidelap
and a secondary member (Excluding the Low Eave Strut). VSR
Clip Fasteners 55320 -
(T-3) 1/4-14 x 1 1/2", 5/16" Hex Hd (Purlins) 56104 - (T-5)
12-24 x 1 1/2" 5/16" Hex Head (Bar Joist) Special Purchase - Fastener with Rigid Board Insulation 2 per
VSR Clip Thermal Blocks 560192 - VSR
1" x 14.25" Thermal Block 1 per
Panel +1 at all VSR Clip Locations (runs). Low Eave VEA10*** – 10’-0” Eave Angle Support with Blanket Insulation.
097196 – 3/8” x 1” ScruBolt building length x 2 097230-*** - (T-2) 12-14 x 1 1/4" 5/16" Hex Head
SS Cap w/Washer = 3 per linear foot Low
Eave with Rigid Board Mastics
and Fasteners at Staggered Laps Note: Quantities
are per lap run (2 required per stager) 0097190UNPNTD
- Nut, 1/4-20 SS Flange Nut = 1.5 per linear foot 0560547 - VSR
Panel Splice Plate (1'-4") = 0.375 per linear foot 0560562 -
Mastic 1/16" x 1" x 40' Roll = 0.0159 per linear foot 0560564 - Mastic
3/16" Dia. x 40' Roll = 0.0047 per linear foot Mastics
and Fasteners at Staggered Laps (West Coast Laps) Note:
Quantities are per lap run (2 required per stager) 0097584UNPNTD
- T-2) #12-14 x 1 1/4", 5/16" Hex Hd, SS Cap w/Washer = 3 per
linear foot 80064- VSR
Panel Stiffener (1'-4") = 0.375 per linear foot 0025392- Tube
Sealant (Gray) = 0.225 per linear foot |
BRII, VSI Wall Covering
Warehouse
Fastener
Spacing Structural
Fasteners (Round
up each Secondary Length to the nearest 1'-0" increment) Each Lap Girt = 1 per foot + 1 Each Low Eave Strut = 2 per foot Each High Eave Strut = 2 per foot Each Rake = 2 per foot Remaining Girts = 1 per foot + 1 Stitch
Fasteners (Round
up each Secondary Length to the nearest 3'-0" increment - 1) Each Side Lap = 2'-6" o.c. Side
Lap Length + 1 Dade
County Stitch Fastener Spacing Stitch
Fasteners (Round
up each Secondary Length to the nearest 3'-0" increment - 1) Each Side Lap = 1'-0" o.c. Side
Lap Length + 1 |
Shadowall, eShadowall Covering
Warehouse
Fastener
Spacing Structural
Fasteners (Round
up each Secondary Length to the nearest 1'-0" increment) Each Lap Girt = 1 per foot + 1 Each Low Eave Strut = 1 per foot + 1 Each High Eave Strut = 1 per foot + 1 Each Rake = 1 per foot + 1 Remaining Girts = 1 per foot + 1 Stitch
Fasteners (Round
up each Secondary Length to the nearest 3'-0" increment - 1) Each Side Lap = 3'-0" o.c. Side
Lap Length + 1 0650173 -
2" eShadowall Spacer (Not at the Base) |
StylWall, eStylWall (Flat /
Fluted) Covering Warehouse
Panel Attachments 0570675 - StylWall Reinforcement Clip Round up each Secondary Length to the nearest
1'-4" increment Each Girt, Base Member, Low Eave Strut, High
Eave Strut, Header, Sill Structural Fastener - 1 per Reinforcement Clip 0097357UNPNTD - (T-1) 1/4-14 x 7/8", 3/8" Hex
Hd w/Washer >7’-6” Girt Space = 1 per Reinforcement Clip Panel Design Load > 23 psf = 1 per Reinforcement Clip Panel Design Load > 41 psf = 1 per Reinforcement Clip and
2’-6” o.c. 0650174 - 1
1/2" eStylWall Spacer |
Moduleze Soffit Warehouse
Panel Attachment Structural Fastener - Each Secondary Member = 1.0 per linear foot + 1 |
MOD36 Liner / Soffit Warehouse
Panel Attachment Structural Fastener (Round up each Secondary Length to the
nearest 1'-0" increment) Each Secondary Member = 1.0 per linear foot + 1 Stitch
Fasteners (Round
up each Secondary Length to the nearest 3'-0" increment - 1) Each Side Lap = 3'-0" o.c. Side
Lap Length + 1 Optional Mastic 025390 - Panlastic w/
Cubes 3/16" x 1/4" x 40' Roll Sidelap (Round up Sidelap
Secondary Lengths to the nearest 1'-0" increment / 40) Secondary (Round up Secondary Lengths to the nearest
1'-0" increment / 40) |
MOD36 at CMR Composite Liner
Warehouse
Panel Attachment Structural Fastener (Round up each Secondary Length to the
nearest 1'-0" increment) Each Secondary Member = 1.0 per linear foot + 1 + 2 fasteners
per panel |
MOD36 at TLS Liner Warehouse
Panel Attachment Structural Fastener - Each Secondary Member = 1.0 per linear foot + 1
Eave Building length x 2 Gable length + 1 Stitch
Fasteners (Round
up each Secondary Length to the nearest 3'-0" increment - 1) Each Side Lap = 3'-0" o.c. Side
Lap Length / 2’-6” +
1 Mastic 560562 - Mastic
1/16" x 1" x 40' Roll Endlap (Round up Endlap Secondary Lengths to the
nearest 1'-0" increment x 1.2 / 40) Sidelap (Round up Sidelap
Secondary Lengths to the nearest 1'-0" increment / 40) 025392
- Panlastic Tube
Sealant - Gray (Round up to a full Tube per building) Endlap
(Round
up Endlap Secondary Lengths to the nearest 1'-0" increment x 0.112 / 20) Ridge
Lap (Round
up Ridge Lap Secondary Length to the nearest 1'-0" increment x 0.555 /
20) Optional CMR Vapor Retarder 560410 - WMPVR (PSKLD) Vapor Retarder = 600'-0"
Long Roll x 6’-6” Wide (6’-0” Coverage) 560532 - WMP-50 Vapor Retarder = 600'-0" Long
Roll x 6’-6” Wide (6’-0” Coverage) |