Secondary - Truss Purlins

(Revised 08/04/2023)

Assembly

Chords

Web Members

End Seats

Connections

Factory Installed Vertical Supports

Field Installed Vertical Support

 

Truss Assembly <<

Truss Depths

Lengths - Minimum to Maximum

Panel Point Spacing

30”

11’-6” through 60’-0”

52”

34”

13’-0” through 60’-0”

60”

40”

15’-6” through 60’-0”

72”

 

Chords <<

Finish

Available Material Thickness

G30

0.060”

0.073”

0.079”

0.088”

0.113”

0.1345”

 

Web Members <<

Web Type

Web Assembly Type

Wall Thickness

Intermediate Web

TIWR – Reinforced

0.068” or 0.090”

TIWU – Unreinforced *

0.068” or 0.090”

TIWDU – Unreinforced**

0.090”

End Web

TEWRA - Reinforced

0.090” or 0.108”

0.090” or 0.108”

TEWUA - Unreinforced

*1.315” OD x 0.090” unreinforced interior webs are invoked only when vertical shear joint loads require a ¼” x 2” x 2” washer.  (Reference DP 4.3.1)

** TIWDU is not automated and must be manually added.

 

 

SNAGHTMLd8abb6

SNAGHTML199cec82

End Seats <<

·        Two Seat Lengths are available: 5” (TESA05) & 10” (TESA10)

·        5” seat available with 9/16” holes

·        10” seat available with 9/16” and 13/16” holes

 

5” SEAT (TESA05)

10” SEAT (TESA10)

Connections <<

·        All web to chord and seat connections use factory installed 5/8”-11 x 1.750” Grade 8 bolts.

·        No field modifications permitted to calibrated factory connections.

·        SED TR022 will be included with every truss order.

SNAGHTML1a4b0b56

 

SNAGHTML4ab81ed

SNAGHTML4c9024b

SNAGHTML4ac92ff                      

SNAGHTML4ad5257

SNAGHTML4ae0145

Factory Installed Vertical Support <<

Field Installed Vertical Support <<